Concentrated phosphate-free liquid formulation designed low pH cleaning of thermal distillation units.
Store in cool, dry and well ventilated area. Keep containers closed. Wash contaminated clothes before re-use. Wash thoroughly after handling. For more information, see the Safety Data Sheet provided with this product.
Add 2 gallons of AWC C-835 for every 100 gallons of water (2% Solution) to adjust pH to 2–2.5 at the discharge of the brine recycle pump. Acidified brine temperatures should be maintained at 48–50 ºC. Measure pH every 15-30 minutes; add AWC C-835 as necessary to maintain the pH range of 2–2.5 throughout the entire cleaning process. Cleaning will be terminated only when brine pH remains stable for two consecutive measurements. System should then be flushed until neutral pH is achieved. If an acid inhibitor such as AWC B-890 is used, best results are achieved by applying and circulating for 1 hour prior to addition of AWC C-835.
For detailed information, download the full product brochure