When do we know if the cleaning of our Reverse Osmosis plant was successful?

  • Hidden

Once the RO membrane system is placed back online after CIP, you can get a relatively good idea by comparing post-cleaning feed pressures and differential pressures for each stage to pre-cleaning values.  The most reliable method would be to observe the trend in your normalized permeate flow chart, since that corrects for changes in temperature, conductivity and % recovery.